8 questions Intermediate

ECADEMY test

17 - Groundwater Pumping

This course test contains 8 questions and can be retaken at any time.

You must answer all questions correctly to pass the test and complete the course.

Start test

Question 3 of 8 Intermediate

By-pass control is an efficient way of performance regulating a pump but what is the downside of the process?

Question 4 of 8 Intermediate

What may cause friction loss in the pipes?

Question 5 of 8 Intermediate

On top of energy-efficient pump operation, how does a frequency drive benefit your installation?

Question 7 of 8 Intermediate

What is the most effective way to stay updated on your pump’s condition?

Question 8 of 8 Intermediate

What kind of riser pipe is most likely to keep itself free from scaling?

Question 8 of 8 Intermediate

Happy with your answers?

Submit your current answers and get the final test result.

Submit

Test results

Congratulations. You have passed the test and completed the 17 - Groundwater Pumping

Achieved badges:

How would you rate this course?

You are welcome to add your rating of this course. Remember that you have to be logged in before you take the test to be able to give your rating.

Continue training Go to MyECADEMY

Sorry. You did not pass the 17 - Groundwater Pumping test this time

How would you rate this course?

You are welcome to add your rating of this course. Remember that you have to be logged in before you take the test to be able to give your rating.

Correct
Q: Why is it a good idea to make a well where the groundwater level is as high as possible?
A: The shorter the distance is to the water the less expensive it is to make the borehole and subsequently to pump the water to the surface
Correct
Q: What can be done to the well if sand continues to enter a well after the well development has been carried out?
A: The well driller can try to run the pump at its maximum capacity in short periods of time over a couple of days
Correct
Q: By-pass control is an efficient way of performance regulating a pump but what is the downside of the process?
A: Energy is wasted as the pump continues to run at full speed
Correct
Q: What may cause friction loss in the pipes?
A: Scaling
Correct
Q: On top of energy-efficient pump operation, how does a frequency drive benefit your installation?
A: It comes with a built-in motor protection
Correct
Q: How is it possible to protect the motor against bad power supply?
A: By means of an electronic motor protection that senses all possible deviations
Correct
Q: What is the most effective way to stay updated on your pump’s condition?
A: Remote online monitoring
Correct
Q: What kind of riser pipe is most likely to keep itself free from scaling?
A: Flex hoses